<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-19 07-47-59
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 4/5, 27 dBuV R-CB
Pilot RDS Phase Difference
6.5 kHz 2.5 kHz 83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
14 kHz 40 kHz 12589 0,0000
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,2 dBr -0,86 dBr -0,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-CB " 250D 9 (Varied) 1 0 0 0 7:47, 19.04.2024
RT
"Ceske pisnicky ktere si zazpivate "
AF EON
88.2, 103.9, 106.4 MHz -
FM Scope Max at: 40 kHz MIN: 14 kHz % above 77 kHz: 0,0000 Acquired: 2024/04/19 7:47:56 Total samples: 12589 Equivalent time: 0:10:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400
FM Scope MAX: -0,4 dBr MIN: -1,2 dBr AVE: -0,86 dBr % above 0,2 dBr: 0,0 Last value: -0,8 dBr (2024/04/19 7:47:56) 07:34 07:36 07:38 07:40 07:42 07:44 07:46 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality